A detector trial needs to show what the controls report and where the marked can actually goes. Ask the supplier for approved challenge samples and agree how quality will identify, handle and account for them. Run the intended product and can format under the authorised conditions.
Trace the marked samples
Record the position of the detector, the challenge sample code and the reject destination. Include accepted control cans and an approved restart. Confirm that rejects can be identified at the final collection point.
| Sample | Expected | Observed |
|---|---|---|
| Reference can | Continues through agreed path | ___ |
| Approved challenge can | Detected and diverted | ___ |
| First checks after restart | Same response and traceability | ___ |
| Reject confirmation | Sample counted at destination | ___ |
Pair the marked sample record with the line time and the can format active at that moment. If the approved sample is detected during stable running but cannot be accounted for after a speed transition, record both runs and ask where the transition changes the tracking sequence. The supplier and quality lead should explain the unresolved sample before acceptance.
Include the detector in the used-line inspection
Check suitability for your can format
Send can drawings, product, rate and test-sample requirements.